Published by Tech Terrace HVAC

A close-up of an air conditioner nameplate with efficiency ratings in Lubbock, Texas

SEER2, HSPF2 and AFUE Explained

What the ratings mean when you get a quote. SEER2, HSPF2, AFUE, and the Southeast minimum, in plain words.

  • ✓Written price before work begins
  • ✓Call direct, no forms to fill
  • ✓Serving Lubbock, Wolfforth & Slaton

What is SEER2, and what does it mean for my quote?

What is SEER2? It is the seasonal efficiency rating for cooling, measured under the current test. It says how much cooling you get for each unit of electricity over a season. A higher number means more cooling for the same power, but only if the rest of the system is right: the ducts, the sizing, and the installation matter as much as the number on the label.

What this page adds: SEER2, HSPF2, and AFUE explained together against the Texas minimums, 14.3 SEER2 and 7.5 HSPF2, and what the ratings mean on a real quote.

When you get a quote in Lubbock, SEER2 is one of the numbers on it, next to the size in tons and the price. The quote should name the rating, the size from a load calculation, and what is included: permit, thermostat, and drain work. Lubbock is in IECC Climate Zone 3B, hot and dry, with about 91 days a year at or above 90 degrees, so cooling governs the peak load, and heating governs the degree days: 3,499 heating degree days against 1,738 cooling degree days.

An air conditioner nameplate with efficiency ratings, photographed close up in a Lubbock, Texas home
An air conditioner nameplate with efficiency ratings: what is SEER2?

Call About SEER2

What is the SEER2 minimum in Texas?

  • Texas is in the Southeast region, and the minimum for a split air conditioner under 45,000 Btu/h is 14.3 SEER2.
  • That is the floor, not a target.
  • Texas has no EER2 requirement.
  • EER2 applies only in the Southwest region: Arizona, California, Nevada, and New Mexico.
RegionSplit AC under 45,000 Btu/hSplit AC 45,000 Btu/h and aboveHeat pump
North14.3 SEER213.8 SEER214.3 SEER2, 7.5 HSPF2
Southeast (Texas)14.3 SEER213.8 SEER214.3 SEER2, 7.5 HSPF2
Southwest14.3 SEER2, 11.7 EER213.8 SEER2, 9.8 EER214.3 SEER2, 7.5 HSPF2

Do not convert an old SEER number into a SEER2 number: the two tests are different, and no conversion turns one into the other. Compare SEER2 with SEER2, and ask for the rating on the quote in writing. AC installation in Lubbock covers sizing and what a complete quote names.

A new outdoor air conditioning unit on a clean concrete pad beside a house in Lubbock, Texas
A new outdoor unit on a clean pad: what is the SEER2 minimum in Texas?

Call About SEER2

What is HSPF2?

HSPF2 is the seasonal efficiency rating for heating by a heat pump, measured under the current test. Where SEER2 covers cooling, HSPF2 covers heating: how much heat the pump moves for each unit of electricity over a season. The minimum for a heat pump is 7.5 HSPF2 nationwide, and the SEER2 minimum of 14.3 applies to the same unit on the cooling side.

A higher HSPF2 means the heat pump heats more efficiently in mild weather, and aux heat takes over less often. Aux heat is the electric backup that runs on the coldest nights, when the pump alone cannot keep up: Lubbock sees about 61 nights a year at or below freezing. A heat pump with a gas furnace as backup is called dual fuel, and heat pump installation in Lubbock explains how that pairing is sized.

Silver ductwork running through a home crawl space in Lubbock, Texas, with an HVAC technician inspecting a duct joint
Silver ductwork in a home: what is HSPF2?

Call About Ratings

What is AFUE?

AFUE is the efficiency rating for a gas furnace: the share of the fuel that becomes heat in the home, and the share that leaves through the flue. A condensing furnace reclaims heat from the exhaust gas and runs more efficiently than a non-condensing furnace, which lets more heat out through the flue. The exact rating is on the manufacturer label, and it is named on your written quote: no two furnaces carry the same number, and the quote is where you see the one you are buying.

AFUE matters most in a cold climate, and Lubbock heating is real: heating degree days exceed cooling degree days here, 3,499 against 1,738. A furnace that runs all winter on a low AFUE rating costs more to run than the same furnace with a higher one, but the rating is only part of the bill: the ducts, the sizing, and the installation matter as much as the number. Ask for the AFUE rating on the quote in writing, next to the SEER2 and HSPF2 numbers.

Call About Ratings

What does the rating mean when you get a quote?

The rating is a starting point, not the decision. A higher SEER2 helps most when the ducts are sealed, the size comes from a load calculation, and the install is done right. An oversized system short cycles, and leaky ducts lose cooled air.

When the quote arrives, check four things:

  • Check the SEER2 rating.
  • Check the size from a load calculation.
  • Check the HSPF2 and AFUE numbers if the quote covers a heat pump or a furnace.
  • Check what is included, permit, thermostat, and drain work.

The federal tax credit for these installs ended 31 December 2025, so a 2026 install does not carry it, and no quote should claim it. If the numbers do not add up, call and ask: the technician walks through the quote in plain words before any work is agreed. Our repair-or-replace guide explains when a new system is the right answer at all.

An HVAC technician showing a written quote on a clipboard to a homeowner in a Lubbock, Texas home
An HVAC technician showing a written quote: what does the rating mean when you get a quote?

Call With Your Quote

SEER2, HSPF2 and AFUE: your questions on ratings and quotes

SEER2 is the seasonal efficiency rating for cooling, measured under the current test. Texas is in the Southeast region, and the minimum for a split air conditioner under 45,000 Btu/h is 14.3 SEER2. For systems of 45,000 Btu/h and above, the minimum is 13.8 SEER2. Texas has no EER2 requirement: EER2 applies only in the Southwest region.

HSPF2 is the seasonal efficiency rating for heating by a heat pump, measured under the current test. The minimum for a heat pump is 7.5 HSPF2 nationwide.

AFUE is the efficiency rating for a gas furnace: the share of the fuel that becomes heat in the home, and the share that leaves through the flue. A condensing furnace reclaims heat from the exhaust and runs more efficiently than a non-condensing furnace. The exact rating is on the manufacturer label, and it is named on your written quote.

No. The ducts, the sizing, and the installation matter as much as the number on the label. An oversized system short cycles, and leaky ducts lose cooled air.

The rating is named on the quote, and a change-out needs a permit from the City of Lubbock. The technician confirms on the call whether your job needs one, what the permit covers, and who handles it, before any work is agreed. The federal tax credit for these installs ended 31 December 2025, so a 2026 install does not carry it.

A homeowner talking with an HVAC technician about a new air conditioning unit in a Lubbock, Texas backyard
A homeowner talking with an HVAC technician: your questions on SEER2, HSPF2 and AFUE.

Call With My Question

A quote in your hand? Call with the numbers

We explain SEER2, HSPF2, and AFUE ratings on a quote in Lubbock. Bring the numbers, and the technician walks through them in plain words.

  • Call and say what the quote names: SEER2, size, and what is included.
  • The technician confirms timing on the call, and the price comes in writing before any work starts.
  • If the system is old, our repair-or-replace guide explains when a new system is the right answer.
  • See what a finished job looks like on our projects page.

Call About SEER2

A clean white HVAC service van parked on a residential street in Lubbock, Texas in the morning
A clean white HVAC service van: a quote in your hand? Call with the numbers.

TECH TERRACE HVAC · CALL NOW

SEER2, HSPF2, AFUE: what to do next about your Lubbock quote

Call now

Got the Numbers? Call With Them

SEER2, HSPF2, and AFUE, named on the quote. Call (806) 240-9865 and ask about the ones on yours.

Call About SEER2

Plan ahead

A Higher Rating Is Not Always a Lower Bill

Start with AC installation in Lubbock, sizing, SEER2, and what a complete quote names.

More short guides live on the blog.

A clean white HVAC service van parked on a residential street in Lubbock, Texas in the morning
A clean white HVAC service van: what to do next about your Lubbock quote.

Find us

Find Tech Terrace HVAC in Lubbock

Tech Terrace HVAC 1203 Donald Preston Drive, Wolfforth, Texas 79382, USA.

Call for AC Installation

Get Help NowServices